HE Qi, ZHAO Hangbin, PENG Jun, SUN Dexin. Application of Multiple Sampling Technology in LWIR Hyperspectral Imaging System[J]. Infrared Technology , 2019, 41(5): 457-461.
Citation: HE Qi, ZHAO Hangbin, PENG Jun, SUN Dexin. Application of Multiple Sampling Technology in LWIR Hyperspectral Imaging System[J]. Infrared Technology , 2019, 41(5): 457-461.

Application of Multiple Sampling Technology in LWIR Hyperspectral Imaging System

More Information
  • Related Articles

    [1]MAO Jingxiang, KONG Jincheng, KONG Linglei, GONG Xiaodan, HUANG Junbo, MA Yingting. Theoretical Calculation and Test Analysis of Noise Equivalent Temperature Difference of Photovoltaic Infrared FPA Detectors[J]. Infrared Technology , 2024, 46(8): 872-878.
    [2]ZHOU Kun, PENG Xiong, ZHONG Xingu, ZHANG Wenhui, LI Qianxi, ZHAO Chao. Identification of Exposed Reinforcement Defects in Bridge Concrete Based on Hyperspectral Imaging[J]. Infrared Technology , 2024, 46(2): 216-224.
    [3]WANG Mingjiu, DAI Xuejing, TANG Chengqing, LU Zhaoyi. Research on Identification Method of Covered Handwriting Based on Hyperspectral Imaging Technology[J]. Infrared Technology , 2023, 45(1): 56-63.
    [4]ZHAO Li, YANG Guoqing, LI Zhou, CUI Tiecheng. Analysis and Example of Operating Range Calculation Method for Point Target in Infrared System[J]. Infrared Technology , 2022, 44(12): 1273-1277.
    [5]JIANG Ting, WANG Ganquan, XI Hongxia. Design of the Low-noise Information Acquisition Circuit for 256×1 LWIR FPA[J]. Infrared Technology , 2016, 38(5): 378-383.
    [6]YUAN Xiao-chun, YANG Zhi-xiong, YU Chun-chao, ZHENG Wei-jian, LEI Zheng-gang, YAN Min. Study of Radiation Calibration for LWIR Hyperspectral Imager Spectrometer[J]. Infrared Technology , 2015, (5): 431-434.
    [7]XIE Bao-rong, FU Yu-tian, ZHANG Ying-qing. Design of the Acquisition System with Low Noise Based on 320 × 256 Long Wavelength Infrared Detector[J]. Infrared Technology , 2010, 32(4): 191-194,203. DOI: 10.3969/j.issn.1001-8891.2010.04.002
    [8]Influence and Analysis of Parameters Set on NETD Test[J]. Infrared Technology , 2009, 31(1): 27-31,34. DOI: 10.3969/j.issn.1001-8891.2009.01.008
    [9]MA Dong-mei, HU Ming-peng, SUN Jun-yue. The Performance Evaluation for IR Staring Array Imaging Systems in Lab[J]. Infrared Technology , 2007, 29(8): 483-487. DOI: 10.3969/j.issn.1001-8891.2007.08.014
    [10]LI Wen-mu, CHEN Xiang-dong, DUAN Xiao-feng. Equivalent Model for Vanadium Oxide Thin Film Uncooled IR Detector[J]. Infrared Technology , 2006, 28(3): 134-138. DOI: 10.3969/j.issn.1001-8891.2006.03.003
  • Cited by

    Periodical cited type(1)

    1. 胡欣,刘瑞杰. 基于降噪技术的高光谱图像实时优化研究. 激光杂志. 2024(08): 164-168 .

    Other cited types(1)

Catalog

    Article views (106) PDF downloads (24) Cited by(2)
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return