ZHAO Qiang, LYU Fu-po, WU Qian, ZHAO Jin-song, WU Xiao-biao. The Error Analysis of the Fold Mirror’s Assembling Position in Infrared Opto-mechanical System[J]. Infrared Technology , 2014, (4): 275-280.
Citation: ZHAO Qiang, LYU Fu-po, WU Qian, ZHAO Jin-song, WU Xiao-biao. The Error Analysis of the Fold Mirror’s Assembling Position in Infrared Opto-mechanical System[J]. Infrared Technology , 2014, (4): 275-280.

The Error Analysis of the Fold Mirror’s Assembling Position in Infrared Opto-mechanical System

More Information
  • Related Articles

    [1]SUN Zhipeng, ZHAO Shiming, SUN Zhiyue. Infrared Imaging Guidance Semi-physical Simulation,Installation Error Analysis, and Correction[J]. Infrared Technology , 2020, 42(2): 139-143.
    [2]NIE Feilong, JIAO Tong. Analysis of the Error Induced by Dynamic Balancing in Rosette Scanning Coordinator[J]. Infrared Technology , 2017, 39(3): 273-278.
    [3]REN Taotao, QIU Yafeng, CHANG Jinbiao, WU Wenbin. Design and Analysis of Infrared Heat Source Turntable System Based on Seeker Test[J]. Infrared Technology , 2017, 39(3): 266-272.
    [4]WANG Dong-he, CHEN Ding-rong, ZHANG Shao-jun, BAI Ji-qing, HE Xin, WEI Zhong-hui. Targeting Error Analysis on Helicopter Photoelectric Platform[J]. Infrared Technology , 2015, 37(11): 926-931.
    [5]LI Xin, CUI Wen-nan, ZHOU Shi-bing. Wide Angle Attitude Measuring Model and Error Analysis of Static-infrared Earth Sensor[J]. Infrared Technology , 2015, 37(1): 73-77.
    [6]ZHAO Zhong-yi, DAI Jing-min, Li Ying. Error Analysis and Calibration of BRDF Measure System[J]. Infrared Technology , 2007, 29(10): 579-583. DOI: 10.3969/j.issn.1001-8891.2007.10.006
    [7]ZHANG Jian, YANG Li, LIU Hui-kai. Effect of Environmental Object on Infrared Temperature Measurement[J]. Infrared Technology , 2005, 27(5): 419-422. DOI: 10.3969/j.issn.1001-8891.2005.05.017
    [8]The Measurement Error Analysis and Modeling of Infraed Scan Camera[J]. Infrared Technology , 2003, 25(6): 14-17. DOI: 10.3969/j.issn.1001-8891.2003.06.004
    [9]Effect of Radiation of the Sun on Infrared Temperature Measurement[J]. Infrared Technology , 2002, 24(1): 34-37. DOI: 10.3969/j.issn.1001-8891.2002.01.010
    [10]Error Analysis of Infrared Measurement[J]. Infrared Technology , 2001, 23(3): 32-34,42. DOI: 10.3969/j.issn.1001-8891.2001.03.009
  • Cited by

    Periodical cited type(2)

    1. 齐鑫,杨智,李冬果. 基于超分辨率重构技术的医学超声波图像增强方法研究. 生物医学工程研究. 2019(01): 59-62 .
    2. 吴宏林,赵淑珍,王建新,张建明,喻小虎. 融合内外特征的图像超分辨率算法. 红外技术. 2019(09): 843-851 . 本站查看

    Other cited types(2)

Catalog

    Article views (109) PDF downloads (11) Cited by(4)