用于准确预测微光像增强器寿命的光灵敏度测量技术

拜晓锋, 郭晖, 杨书宁, 朱宇峰, 石峰, 侯志鹏, 黄武军, 孟庆运

拜晓锋, 郭晖, 杨书宁, 朱宇峰, 石峰, 侯志鹏, 黄武军, 孟庆运. 用于准确预测微光像增强器寿命的光灵敏度测量技术[J]. 红外技术, 2018, 40(12): 1121-1124.
引用本文: 拜晓锋, 郭晖, 杨书宁, 朱宇峰, 石峰, 侯志鹏, 黄武军, 孟庆运. 用于准确预测微光像增强器寿命的光灵敏度测量技术[J]. 红外技术, 2018, 40(12): 1121-1124.
BAI Xiaofeng, GUO Hui, YANG Shuning, ZHU Yufeng, SHI Feng, HOU Zhipeng, HUANG Wujun, MENG Qingyun. Integral Sensitivity Measurement Technique for Accurately Predicting the Lifetime of a Low-light-level Image Intensifier[J]. Infrared Technology , 2018, 40(12): 1121-1124.
Citation: BAI Xiaofeng, GUO Hui, YANG Shuning, ZHU Yufeng, SHI Feng, HOU Zhipeng, HUANG Wujun, MENG Qingyun. Integral Sensitivity Measurement Technique for Accurately Predicting the Lifetime of a Low-light-level Image Intensifier[J]. Infrared Technology , 2018, 40(12): 1121-1124.

用于准确预测微光像增强器寿命的光灵敏度测量技术

基金项目: 总装实验室基金
详细信息
  • 中图分类号: TN223

Integral Sensitivity Measurement Technique for Accurately Predicting the Lifetime of a Low-light-level Image Intensifier

  • 摘要: 光阴极光灵敏度的测量误差大小对微光像增强器寿命预测结果影响很大,高精确度的光灵敏度测量可以实现微光像增强器寿命的准确预测.本文通过分析光阴极光灵敏度测量原理、方法和装置特性,利用光灵敏度误差分配方法,在保证满足寿命预测所需光灵敏度测量误差的前提下,确定了一种合成测量误差为3.8%的光灵敏度测量方案,基于该方案预测的微光像增强器寿命与实际寿命试验验证结果的相对偏差不超过2%,为提高微光像增强器的工程研制效率提供了有效的检测手段.
  • 期刊类型引用(4)

    1. 李书涵,陈文娥,王重霄,陈卫军,宋德,李野. EBCMOS钝化层表面残气吸附特性. 半导体光电. 2023(06): 901-906 . 百度学术
    2. 郝芳,张平,杨海金,王瑶,卞臻臻,詹江,郑伟,梁琦. 浅析光纤倒像器固有误差对应用的影响. 应用光学. 2022(06): 1153-1157 . 百度学术
    3. 拜晓锋,程宏昌,何开远,韩坤,杨书宁,李军国,陈旭浪,党小刚,王磊. 微光像增强器积分灵敏度单次测量误差分析. 应用光学. 2020(04): 791-795 . 百度学术
    4. 姚泽,程宏昌,李涛,周玉鉴,黄武军,李丹. 基于P31荧光粉的像增强器余辉测量方法研究. 应用光学. 2020(04): 796-800 . 百度学术

    其他类型引用(1)

计量
  • 文章访问数:  156
  • HTML全文浏览量:  25
  • PDF下载量:  32
  • 被引次数: 5
出版历程

目录

    /

    返回文章
    返回