用于准确预测微光像增强器寿命的光灵敏度测量技术

拜晓锋, 郭晖, 杨书宁, 朱宇峰, 石峰, 侯志鹏, 黄武军, 孟庆运

拜晓锋, 郭晖, 杨书宁, 朱宇峰, 石峰, 侯志鹏, 黄武军, 孟庆运. 用于准确预测微光像增强器寿命的光灵敏度测量技术[J]. 红外技术, 2018, 40(12): 1121-1124.
引用本文: 拜晓锋, 郭晖, 杨书宁, 朱宇峰, 石峰, 侯志鹏, 黄武军, 孟庆运. 用于准确预测微光像增强器寿命的光灵敏度测量技术[J]. 红外技术, 2018, 40(12): 1121-1124.
BAI Xiaofeng, GUO Hui, YANG Shuning, ZHU Yufeng, SHI Feng, HOU Zhipeng, HUANG Wujun, MENG Qingyun. Integral Sensitivity Measurement Technique for Accurately Predicting the Lifetime of a Low-light-level Image Intensifier[J]. Infrared Technology , 2018, 40(12): 1121-1124.
Citation: BAI Xiaofeng, GUO Hui, YANG Shuning, ZHU Yufeng, SHI Feng, HOU Zhipeng, HUANG Wujun, MENG Qingyun. Integral Sensitivity Measurement Technique for Accurately Predicting the Lifetime of a Low-light-level Image Intensifier[J]. Infrared Technology , 2018, 40(12): 1121-1124.

用于准确预测微光像增强器寿命的光灵敏度测量技术

基金项目: 总装实验室基金
详细信息
  • 中图分类号: TN223

Integral Sensitivity Measurement Technique for Accurately Predicting the Lifetime of a Low-light-level Image Intensifier

  • 摘要: 光阴极光灵敏度的测量误差大小对微光像增强器寿命预测结果影响很大,高精确度的光灵敏度测量可以实现微光像增强器寿命的准确预测.本文通过分析光阴极光灵敏度测量原理、方法和装置特性,利用光灵敏度误差分配方法,在保证满足寿命预测所需光灵敏度测量误差的前提下,确定了一种合成测量误差为3.8%的光灵敏度测量方案,基于该方案预测的微光像增强器寿命与实际寿命试验验证结果的相对偏差不超过2%,为提高微光像增强器的工程研制效率提供了有效的检测手段.
  • 期刊类型引用(4)

    1. 曾昌行,陈军,黄一彬,王明伟,任海,甘游宇. 制冷型红外探测器杜瓦辐射热的角系数计算. 红外与激光工程. 2024(06): 48-58 . 百度学术
    2. 曾智江,杨力怡,郝振贻,徐琳,范广宇,范崔,李俊,李雪,龚海梅. 集成冷光学的双波段杜瓦组件技术. 中国激光. 2023(23): 237-245 . 百度学术
    3. 陈俊林,王小坤,曾智江,孙闻,张冬冬,甄红楼,李雪. 长波QWIP-LED量子阱红外探测器杜瓦研制. 激光与红外. 2020(07): 846-850 . 百度学术
    4. 李俊,王小坤,孙闻,林加木,曾智江,沈一璋,范广宇,丁瑞军,龚海梅. 超长线列双波段红外焦平面探测器杜瓦封装技术研究. 红外与激光工程. 2018(11): 173-179 . 百度学术

    其他类型引用(1)