Design of Portable Infrared thermometer and Temperature Compensation Technology

  • Received Date: 2020-10-10
  • Rev Recd Date: 2021-01-12
  • Publish Date: 2021-06-20
  • Infrared thermometers are popular because of their safety, hygiene, and high efficiency. However, commercial infrared thermometers have large measurement errors and high cost, so their application is limited. Considering this, this paper first analyzes various factors that affect the measurement accuracy of an infrared thermometer and gives the calculation results of the specific influence degree. Then, using STM32F407 MCU as the control core, an MLX90615 infrared sensor, DS18B20 integrated temperature sensor, and HC-SR04 ultrasonic sensor to obtain information, a cheap and reliable portable infrared thermometer for hospitals and families is designed, and a method of temperature compensation is provided. Finally, the reliability of the system design was verified by testing. The test results show that the maximum comprehensive error is less than 0.15℃, which has definite practical value and reference value.
  • loading
  • [1]
    杨清志, 张喜红. 基于Si7053的智能数字体温计的设计[J]. 黑河学院学报, 2016, 7(3): 123-125. doi:  10.3969/j.issn.1674-9499.2016.03.033

    YANG Qingzhi, ZHANG Xihong. Design of a intelligent digital thermometer based on Si7053[J]. Journal of Heihe University, 2016, 7(3): 123-125. doi:  10.3969/j.issn.1674-9499.2016.03.033
    [2]
    郑英, 李香菊, 王迷迷, 等. 基于NTC和ZigBee技术的病房病人体温监测系统设计[J]. 现代电子技术, 2016, 39(4): 26-28. https://www.cnki.com.cn/Article/CJFDTOTAL-XDDJ201604008.htm

    ZHENG Ying, LI Xiangju, WANG Mimi, et al. Design of patients temperature monitoring system based on NTC and ZigBee technology[J]. Modern Electronics Technique, 2016, 39(4): 26-28. https://www.cnki.com.cn/Article/CJFDTOTAL-XDDJ201604008.htm
    [3]
    赵志刚, 王鑫, 彭廷海, 等. 国外中长波双波段红外成像技术的发展及应用[J]. 红外技术, 2020, 42(4): 312-319. http://hwjs.nvir.cn/article/id/hwjs202004002

    ZHAO Zhigang, WANG Xin, PENG Tinghai, et al. Status Quo and application of middle and long wave dual-band infrared imaging technologies in occident[J]. Infrared Technology, 2020, 42(4): 312-319. http://hwjs.nvir.cn/article/id/hwjs202004002
    [4]
    Sivanandam S, Anburajan M, Venkatraman B, et al. Medical thermography: a diagnostic approach for type 2 diabetes on non-contact infrared thermal imaging[J]. Endocrine, 2012, 42(2): 343-351. doi:  10.1007/s12020-012-9645-8
    [5]
    袁浩期, 李杨, 王俊影, 等. 基于红外热像的行人面部温度高精度检测技术[J]. 红外技术, 2019, 41(12): 1181-1186. http://hwjs.nvir.cn/article/id/hwjs201912015

    YUAN Haoqi, LI Yang, WANG Junying, et al. High precision detection technology of pedestrian face temperature based on infrared thermal imaging[J]. Infrared Technology, 2019, 41(12): 1181-1186. http://hwjs.nvir.cn/article/id/hwjs201912015
    [6]
    丁岩. 红外体温测量管理系统的设计[D]. 呼和浩特: 内蒙古大学, 2017.

    DING Yan. Design of Infrared Temperature Measurement and Management System[D]. Hohhot: Inner Mongolia University, 2017.
    [7]
    陈昊. 红外耳温计设计方案与校准结果不确定度评定的研究[D]. 保定: 河北大学, 2014.

    CHEN Hao. Design of Infrared Ear Thermometer and the Evaluation of the Uncertainty of the Results Calibration[D]. Baoding: Hebei University, 2014.
    [8]
    孙成, 潘明强, 王阳俊, 等. 噪声对红外测温性能的影响研究[J]. 红外技术, 2019, 41(4): 370-376. http://hwjs.nvir.cn/article/id/hwjs201904012

    SUN Cheng, PAN Mingqiang, WANG Yangjun, et al. Influence of noise on infrared temperature measurement performance[J]. Infrared Technology, 2019, 41(4): 370-376. http://hwjs.nvir.cn/article/id/hwjs201904012
    [9]
    Melexis Co. Digital plug & play infrared thermometer in ultra small TO-Can[EB/OL] https://www.melexis.com/en/product/MLX90615/-Digital-Plug-Play-Infrared-Thermometer-Ultra-Small-TO-Can.
    [10]
    葛泽勋. 医用红外测温仪及其关键技术研究[D]. 长春: 长春理工大学, 2019.

    GE Zexun. Research on Medical Infrared Thermometer and the Key Technology[D]. Changchun: Changchun University of Science and Technology, 2019.
    [11]
    杨清志, 蒋伟, 许春雷. 基于多智能体的交直流混合微电网监控设计与分层控制研究[J]. 高电压技术, 2020, 46(7): 2327-2339. https://www.cnki.com.cn/Article/CJFDTOTAL-GDYJ202007009.htm

    YANG Qingzhi, JIANG Wei, XU Chunlei. Monitoring design and research on hierarchical control of AC/DC hybrid microgrid based on multi-agent[J]. High Voltage Engineering, 2020, 46 (7): 2327-2339. https://www.cnki.com.cn/Article/CJFDTOTAL-GDYJ202007009.htm
    [12]
    康慧雯. 基于热像测温原理的体温筛检关键技术的研究[D]. 天津: 天津大学, 2011.

    KANG Huiwen. Based on thermal imaging temperature measuring principle body technology screening key technology research[D]. Tianjin: Tianjin University, 2011.
    [13]
    杜玉玺, 胡振琪, 葛运航, 等. 距离对不同强度热源红外测温影响及补偿[J]. 红外技术, 2019, 41(10): 976-981. http://hwjs.nvir.cn/article/id/hwjs201910014

    DU Yuxi, HU Zhenqi, GE Yunhang, et al. Distance influence and compensation of infrared temperature measurement with different intensity heat sources[J]. Infrared Technology, 2019, 41(10): 976-981. http://hwjs.nvir.cn/article/id/hwjs201910014
    [14]
    席剑辉, 姜瀚. 基于RBF网络的红外多光谱辐射温[J]. 红外技术, 2020, 42(10): 963-968. http://hwjs.nvir.cn/article/id/hwjs202010008

    XI Jianhui, JIANG Han. Infrared multispectral radiation-temperature measurement based on RBF network[J]. Infrared Technology, 2019, 41(10): 976-981. http://hwjs.nvir.cn/article/id/hwjs202010008
    [15]
    白友龙. 高精度红外体温计的设计与实现[D]. 锦州: 辽宁工业大学, 2014.

    BAI Youlong. Design and Implementation of High-precision Infrared Thermometer[D]. Jinzhou: Liaoning University of Technology, 2014.
    [16]
    魏坦勋. 人体非接触测温综合误差补偿技术的研究与实现[D]. 杭州: 杭州电子科技大学, 2013.

    WEI Tanxun. Research and Implementation of Comprehensive Error Compensation Technology Non-Contact Temperature Measurement[D]. Hangzhou: Hangzhou Dianzi University, 2013.
    [17]
    苏建奎, 桂星雨. 医用红外体温测量仪的现状与发展[J]. 医疗卫生装备, 2016, 37(1): 110-112, 129. https://www.cnki.com.cn/Article/CJFDTOTAL-YNWS201601039.htm

    SU Jiankui, GUI Xingyu. Present status and trend of medical infrared temperature measuring instrument[J]. Chinese Medical Equipment Journal, 2016, 37(1): 110-112, 129. https://www.cnki.com.cn/Article/CJFDTOTAL-YNWS201601039.htm
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Figures(13)  / Tables(3)

    Article Metrics

    Article views (994) PDF downloads(82) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return