[1]陆旭,罗汉武,李文震,等.电力金具图像故障状态评估[J].红外技术,2020,42(7):632-636.[doi:10.11846/j.issn.1001_8891.202007005]
 LU Xu,LUO Hanwu,LI Wenzhen,et al.Estate Evaluation of Image Fault of Electric Power Fittings[J].Infrared Technology,2020,42(7):632-636.[doi:10.11846/j.issn.1001_8891.202007005]
点击复制

电力金具图像故障状态评估
分享到:

《红外技术》[ISSN:1001-8891/CN:CN 53-1053/TN]

卷:
42卷
期数:
2020年第7期
页码:
632-636
栏目:
出版日期:
2020-07-23

文章信息/Info

Title:
Estate Evaluation of Image Fault of Electric Power Fittings
文章编号:
1001-8891(2020)07-0632-05
作者:
陆旭1罗汉武1李文震1张海龙2吴启瑞2雷丞3
1. 国网内蒙古东部电力有限公司;
2. 国网电力科学研究院武汉南瑞有限责任公司;
3. 武汉三江中电科技有限责任公司

Author(s):
LU Xu1LUO Hanwu1LI Wenzhen1ZHANG Hailong2WU Qirui2LEI Cheng3
1. State Grid East Inner Mongolia Electric Power Supply Co.Ltd. ;
2. Wuhan Nari Limited Liability Company of State Grid Electric Power Research Institute;?
3. Wuhan Sanjiang China Electronics Technology Co., Ltd.

关键词:
电力金具紫外成像电晕放电图像处理状态评估
Keywords:
electric power fittings ultraviolet imaging corona discharge image processing estate evaluation
分类号:
TM76
DOI:
10.11846/j.issn.1001_8891.202007005
文献标志码:
A
摘要:
电力金具是输变电工程的关键部件,在温度、风沙等环境因素作用下,因结构缺陷会导致电晕放电,最终影响输变电线路的安全运行。基于电晕试验工作平台,采用图像融合和图像处理技术,对放电光斑进行特征提取和状态评估。研究结果表明:光斑面积与放电量呈线性关系;电力金具放电阶段由电晕阶段,历经小电弧阶段,最终发展到强烈火花放电阶段;当增益为70%,观测距离为10 m时,3个阶段的放电光斑面积分别约为1000像素、5000像素和10000像素;根据紫外图像特征,电力金具的状态评估分为无缺陷,一般缺陷,严重缺陷,紧急缺陷4个状态。该研究成果为电力金具安全评估提供技术支撑。
Abstract:
Electric power fittings are the critical components of power transmission and transformation structures. Under the action of environmental factors, such as temperature and sandstorm, structural defects can lead to corona discharge, which can ultimately affect the safe operation of power transmission and transformation lines. Based on the working platform of a corona test, the feature extraction and evaluation of discharge spots were carried out in this study using image fusion and image processing technology. The results prove that the relationship between the spot area and discharge capacity is linear. The discharge stages of electric power fittings develop from the corona stage to a small electric arc stage, and finally, to a strong spark discharge stage. When the observation distance is 10 m, the gain is 70%, and the discharge spot areas of three stages are approximately 1000, 5000, and 10000 pixels. Based on the characteristics of the ultraviolet image, the state of electric power fittings can be divided into four states: no defect, general defect, serious defect, and emergency defect. The study results provide technical support for the safety evaluation of electric power fittings.

参考文献/References:

[1] 邓久艳, 张宏杰, 李若斓. 基于紫外成像的憎水性表面电晕起始放电研究[J]. 绝缘材料, 2016, 49(4): 50-54.
DENG Jiu, ZHANG Hongjie, LI Ruolan. Study on initial discharge of hydrophobic surface corona based on UV imaging[J]. Insulating Materials, 2016, 49(4): 50-54.
[2] 陈磊, 周仿荣, 马仪, 等. 悬式复合绝缘子电晕放电紫外图像光斑面积[J]. 高压电器, 2013, 49(8): 60-67.
CHEN Lei, ZHOU Fangrong, MA Yi, et al. Ultraviolet image facular area vary characteristic and apparent discharge estimation of suspension composite insulator corona[J]. High Voltage Apparatus, 2013, 49(8): 60-67.
[3] 徐长福, 周广洋, 胡成博, 等. 紫外成像图谱参数量化提取改进算法的研究[J]. 智慧电力, 2017, 45(11): 52-56.
XU Changfu, ZHOU Guangyang, HU Chengbo, et al. Study on improved extraction algorithm for parameter quantization of ultraviolet imaging spectra[J]. Grid Analysis & Study, 2017, 45(11): 52-56.
[4] 李炼炼, 孟刚, 邓慰, 等. 输变电设备电晕放电紫外图谱量化参数提取[J]. 高压电器, 2017, 53(12): 229-235.
LI Lianlian, MENG Gang, DENG Wei, et al. Quantification parameters extraction from ultraviolet image of corona discharge of power transmission and transformation equipment[J]. High Voltage Apparatus, 2017, 53(12): 229-235.
[5] 贺振华, 王玮, 黄文武, 等. 两种紫外成像仪检测电晕放电的对比研究[J]. 高压电器, 2014, 50(8): 80-86.
HE Zhenhua, WANG Wei, HUANG Wenwu, et al. Comparative Study on Corona Discharge Detection with Two Ultraviolet Imagers[J]. High Voltage Apparatus, 2014, 50(8): 80-86.
[6] 黄文武, 贺振华, 蔡炜, 等. 基于紫外成像技术的棒?板间隙放电环境因素研究[J]. 高电压技术, 2015, 41(8): 2788-2794.
HUANG Wenwu, HE Zhenhua, CAI Wei, et al. Study on the environmental factors of rod-plane gap discharge based on UV imaging[J]. High Voltage Engineering, 2015, 41(8): 2788-2794.
[7] 齐磊, 符瑜科, 李小萌, 等. 气压和湿度对复合电压下换流阀高压电极起晕电压影响试验[J]. 高电压技术, 2019, 45(1): 82-90.
QI Lei, FU Yuke, LI Xiaomeng, et al. Effects of air pressure and humidity on corona onset voltage of high voltage electrode of converter valve under combined ac and dc voltage[J]. High Voltage Engineering, 2019, 45(1): 82-90.
[8] 黄荣辉, 张宏钊, 李勋, 等. 基于紫外成像法的绝缘子电晕放电影响因素试验研究[J]. 水电能源科学, 2015, 33(11): 180-182, 170.
HUANG Ronghui, ZHANG Hongzhao, LI Xun, et al. Test study on factors influencing insulator corona discharge with ultraviolet imagery method[J]. Water Resources and Power, 2015, 33(11): 180-182, 170.
[9] 李林发, 穆卡, 黄荣辉, 等. 基于紫外成像的电晕放电参数变化特性及距离修正方法研究[J]. 水电能源科学, 2015, 33(11): 183-187.
LI Linfa, MU Ka, HUANG Ronghui, et al. Study on parameter vitiation characteristics and distance correction of corona discharge based on ultraviolet imagery[J]. Water Resources and Power, 2015, 33(11): 183-187.
[10] 刘云鹏, 周广洋, 黄世龙, 等. 基于紫外成像的高海拔分裂导线电晕起始特性研究[J]. 电测与仪表, 2017, 54(19): 54-58, 101.
LIU Yunpeng, ZHOU Guangyang, HUANG Shilong, et al. Study on corona onset characteristics of bundle conductorsin high altitude area based on equivalent spot area[J]. Electrical Measurement & Instrumentation, 2017, 54(19): 54-58, 101.
[11] 刘云鹏, 纪欣欣, 裴少通, 等. 基于稀疏表示的绝缘子紫外图谱闪络状态分类评估方法[J]. 高电压技术, 2018, 44(10): 3352-3358.
LIU Yunpeng, JI Xinxin, PEI Shaotong, et al. Method for Evaluating Flashover State of Insulator Ultraviolet Image Based on Sparse Representation[J]. High Voltage Engineering, 2018, 44(10): 3352-3358.
[12] 李建波, 高文胜, 刘卫东. 直流GIL绝缘子表面附着金属颗粒局部放电发展过程及严重程度评估[J]. 高压电器, 2018, 54(5): 9-16.
LI Jianbo, GAO Wensheng, LIU Weidong. Evolution Process and Severity Assessment of the Partial Discharge Caused by Immobilized Metal Particles on DC GIL Insulator Surface[J]. High Voltage Apparatus, 2018, 54(5): 9-16.
[13] 王胜辉, 牛雷雷, 李浩, 等. 基于放电紫外成像特征的污秽线路盘形绝缘子绝缘状态评估[J]. 高压电器, 2019, 55(2): 201-207.
WANG Shenghui, NIU Leilei, LI Hao, etal. Insulation Condition Evaluation of Contaminated Disc Insulator for Transmission Lines Based on the Characteristic of Discharge UV Imaging Characteristics[J]. High Voltage Apparatus, 2019, 55(2): 201-207.
[14] 赵建平, 邓鹤鸣, 张伟, 等. 线路金具沙粒磨损模拟试验:试验设置与电晕分析[J]. 高电压技术, 2018, 44(9): 2904-2910.
ZHAO Jianping, DENG Heming, ZHANG Wei, et al. Sand Erosion Simulation Experiments on Link Hardware of Transmission Lines: Test Setting and Corona Analysis[J]. High Voltage Engineering, 2018, 44(9): 2904-2910.
[15] 陈磊, 邓慰, 周仿荣, 等. 基于紫外成像的电晕放电海拔因素的研究[J]. 电瓷避雷器, 2013(6): 124-129.
CHEN Lei, DENG Wei, ZHOU Fangrong, et al. Study on the Altitude Factors of Corona Discharge Based on UV Imaging[J]. Insulators and Surge Arresters, 2013(6): 124-129.

备注/Memo

备注/Memo:
收稿日期:2019-07-31;修订日期:2020-06-05.
作者简介:陆旭(1970-),辽宁锦州人,男,硕士学位,高级工程师,从事电网信息通信以及人工智能电网图像故障检测。E-mail: 1257345953@qq.com。