[1]潘京生.空间和时间灵敏的微通道板光子探测器[J].红外技术,2018,40(11):1025-1032.[doi:10.11846/j.issn.1001_8891.201811001]
 PAN Jingsheng.Microchannel PlatePhoton Detector with Spatial and Temporal Sensitivity[J].Infrared Technology,2018,40(11):1025-1032.[doi:10.11846/j.issn.1001_8891.201811001]
点击复制

空间和时间灵敏的微通道板光子探测器
分享到:

《红外技术》[ISSN:1001-8891/CN:CN 53-1053/TN]

卷:
40
期数:
2018年第11期
页码:
1025-1032
栏目:
出版日期:
2018-11-21

文章信息/Info

Title:
Microchannel PlatePhoton Detector with Spatial and Temporal Sensitivity
文章编号:
1001-8891(2018)11-1025-08
作者:
潘京生12
1. 微光夜视技术重点实验室;2. 北方夜视技术股份有限公司
Author(s):
PAN Jingsheng12
1.North Night Vision Technology Corp., Ltd.;
2.Science and Technology on Low-Light-Level Night Vision Laboratory

关键词:
微通道板光子计数成像探测器空间分辨时间分辨
Keywords:
microchannel platephoto counting imaging detectorspatial resolutiontemporal resolution
分类号:
TN223
DOI:
10.11846/j.issn.1001_8891.201811001
文献标志码:
A
摘要:
微通道板(Microchannel Plate,MCP)探测器具备单光子(粒子)灵敏的计数成像探测能力,以及多种类型的读出方式和构造及封装形式的选择。MCP的特征结构决定其具有高空间分辨和快时间响应能力。快速多通道全并行数据处理电子学的应用,使MCP光子探测器的空间和时间分辨性能得到显著提高,而借助于像增强器高真空封管工艺制程,结合多种光电阴极的选择,构造标准化封装组件及模块,以便于针对不同应用时的灵活配置及专门优化,将MCP光子探测器拓展到多种学科领域应用,成为对多种微弱辐射物进行高空间分辨和时间分辨的计数成像探测的一个有效工具。
Abstract:
A microchannel plate (MCP) detector is capable of single photon (particle) sensitivity-counting image detection while employing several readout methods and using configuration and encapsulation format selection was developed in this study. The small feature configuration of MCP detectors enables their high spatial resolution and very fast temporal response. With the integration of fast multi-channel front-end ASICs, the spatial resolution and temporal sensitivity of MCP detectors have improved considerably. In addition to the standard high vacuum tube sealing process applied to the manufacture of image intensifiers, the selection of various photocathodes, the standard package of components and modules, and flexible configuration and special optimization have enabled MCP photon detectors to become powerful tools used to perform high spatial and temporal resolution counting imaging detection with various weak radiators.

参考文献/References:

[1] Lapington J S, Smith A D, Walton D M, et al. Microchannel Plate Pore Size Limited Imaging with Ultra-thin Wedge and Strip Anode[J]. IEEE Transactions on Nuclear Science, 1987, NS-34(1): 431-434.
[2] Jagutzki O, Barnstedt J, Spillmann U, et al. Fast Position and Time Sensitive Read-out of Image Intensifiers for Single Photon Detector[C]//Proc. SPIE, 1999, 3764: 61-69.
[3] Czasch A, Milnes J, Hay N. Position- and time-sensitive single photon detector withdelay-line readout[J]. Nuc Instr. and Meth A., 2007, 580: 1066-1070.
[4] Siegmund O, Tremsin A, Vallerga J, et al. Microchannel plate cross-strip detectors with high spatial and temporal resolution[J]. Nuc Instr. and Meth A., 2009, 610(1): 118-122.
[5] Jagutzki O, Lapington J S, Worth L B C, et al. Position sensitive anodes for MCP read-out using induced charge measurement[J]. Nuc Instr. and Meth A., 2002, 477: 256-261.
[6] Anton S Tremsin, Oswald H W Siegmund, John V Vallerga, et al. High Speed Multichannel Charge Sensitive Data AcquisitionSystem with Self-Triggered Event Timing[J]. IEEE Trans Nucl Sci., 2009, 56(3): 1148-1152.
[7] Va’Vra J, Benitez J, Leith D W G S, et al. A 30 ps timing resolution for single photons with multi-pixel Burle MCP-PMT[J]. Nuclear Inst& Methods in Physics Research A, 2007, 572(1): 459-462.
[8] Siegmund O H W, Mc Phate J B, Tremsin A S, et al. 20 cm Sealed Tube Photon Counting Detectors with Novel Microchannel Plates for Imaging and Timing Applications[J]. Physics Procedia, 2012, 37: 803-810.
[9] Siegmund O, Tremsin A, Vallerga J, et al. Microchannel plate cross-strip detectors with high spatial andtemporal resolution[J]. Nuclear Instrum Methods Phys Res A, 2009, 610(1): 118-122.?
[10] Siegmund O H W, Gummin M A, Naletto G, et al. Performance of the double delay line microchannel plate detectors for the Far-Ultraviolet Spectroscopic Explorer[C]//Proc of SPIE, 1997, 4139(1): 149-162.
[11] Siegmund O H W, Jelinsky P N, Jelinsky S R, et al. High-resolution cross delay line detectors for the GALEX mission[C]//EUV, X-Ray, and Gamma-Ray Instrumentation for Astronomy X. International Society for Optics and Photonics, 1999, 3765: 429-440.
[12] Stock J, Siegmund O, Hull J, et al. Cross-delay-line microchannel plate detect detectors for theSpectrographic Imager on the IMAGE satellite[C]//Proc SPIE, 1998, 3445: 407-414.
[13] Siegmund O H W, Gummin M A, Sasseen T, et al. Microchannel plates for the UVCS and SUMER instruments on the SOHO satellite[C]//Proc. SPIE, 1995, 2518: 334-55
[14] Vallerga J, Zaninovich J, Welsh B, et al. The FUV detector for the cosmic origins spectrograph on the Hubble Space Telescope[J]. Nuc. Instr. and Meth. A., 2002, 477(1-3): 551-555
[15] Siegmund O, Vallerga J, Jelinsky P, et al. Cross Delay Line Detectors for High Time Resolution Astronomical Polarimetry and Biological Fluorescence Imaging[C]//IEEE, Nuclear Science Symposium and Medical Imaging Conference, 2005: 14-55.
[16] Michalet X, Siegmund O H W, Vallerga J V, et al. Photon-counting H33Ddetector for biological fluorescence imaging[J]. Nuc. Instr. and Meth. A., 2006, 567(1): 133-136.
[17] Tremsin A S, Lebedev G V, Siegmund O H W, et al. High spatial and temporal resolution photon/electroncounting detector for synchrotron radiation research[J]. Nucl. Instr. and Meth. A, 2000, 6580: 853-857.
[18] Garíc L C. Testing micro-channel plate detectors for the particle identification upgrade of LHCb[J]. Nuc Instr. and Meth A., 2012, 695: 398-402.
[19] Credo T, Frisch H, Sanders H, et al. Picosecond time-of-flight measurement for colliders using Cherenkov light[C]//Nuclear Science Symposium Conference Record. IEEE, 2005, 1: 586-590.
[20] Genat J F, Varner G, Tang F, et al. Signal processing for picosecond resolution timing measurements[J]. Nuclear Inst& Methods in Physics Research A, 2008, 607(2): 387-393.
[21] Seitz B, Britting A, Cowie E, et al. Photon Detection Systems for Modern Cherenkov Detectors[J]. Physics Procedia, 2012, 37(12): 796-799.
[22] Céolin D, Chaplier G, Lemonnier M, et al. High spatial resolution two-dimensional position sensitive detector for the performance of coincidence experiments[J]. Review of Scientific Instruments, 2005, 76(4): 1501.
[23] Kim H, Chen C T, Frisch H, et al. A Prototype TOF PET Detector Module Using a Micro-Channel Plate Photomultiplier Tube with Waveform Sampling[J]. Nuclear Inst. & Methods in Physics Research A, 2012, 662(1): 26-32.
[24] Seitz B. Position sensitive photon detectors for nuclear physics, particle physics and healthcare applications[J]. Journal of Instrumentation, 2012, 7(1): C01031.
[25] Wiza J. Microchannel Plate Detector[J]. Nuc. Instu. & Meth. A, 1979, 162: 587-601.
[26] PAN J, YANG Y, TIAN Y, et al. High Detection Efficiency Neutron Sensitive Microchannel Plate[J]. Journal of Instrumentation, 2013, 8(1): P01015.
[27] Siegmund O, Vallerga J, Wargelin B. Background events in microchannel plates[J]. IEEE Trans. Nucl. Sci., 1988, NS-35: 524-528.
[28] Lapington J S, Milnes J S. Novel electronic readout systems for photon-counting imagers[C]//Image Intensifiers and Applications II. International Society for Optics and Photonics, 2000: 120-128.
[29] John Vallerga, Jason McPhate. Optimization of the Readout Electronics forMicrochannel Plate Delay Line Anodes[C]//Proc. SPIE, 2000, 4139: 34-42.
[30] Jagutzki O, Mergel V, Ullmann-Pfleger K, et al. A broad-application microchannel-plate detector system foradvanced particle or photon detection tasks: large areaimaging, precise multi-hit timing information and highdetection rate[J]. Nuc Instr. and Meth. A, 2002, 477: 244-249.
[31] Hervé Grabas, Razib Obaid, Eric Oberla, et al. RF strip-line anodes for Ps eclarge-area MCP-based photodetectors[J]. Nuc Instr. and Meth. A, 2013, 711: 124-131.
[32] Genat J, Varner G, TANG Fukun, et al. Signal Processing for Pico-second Resolution Timing Measurements[J]. Nuc Instr. and Meth. A., 2009, 607: 387-393.
[33] Akatsu M, Enari Y, Hayasaka K, et al. MCP-PMT timing property for single photons[J]. Nuc Instr. and Meth. A., 2004, 528:763-775.
[34] John T Anderson E, Karen Byrum, Gary Drake, et al. New Developments in Fast-Sampling Readout of Micro-Channel Plate Based Large Area Pico-second Time-of-Flight Detectors[C]//IEEE Nuclear Science Symposium Conference Record, 2008: 2478-2481.
[35] Conti L, Barnstedt J, Hanke L, et al. MCP detector development for UV space missions[J]. Astrophys Space Sci., 2018, 363: 63.
[36] Lapington J S, Howorth J R, Milnes J S. A reconfigurable image tube using an external electronic image readout[C]//Infrared and Photoelectronic Imagers and Detector Devices. International Society for Optics and Photonics, 2005: 588109-588109-10.
[37] Dixit M. Development of high resolution Micro-Pattern Gas Detectors with wide readout pads[J]. Journal of Instrumentation, 2010, 5(3): P03008.
[38] Angelico E, Seiss T, Adams B, et al. Capacitively coupled pickup in MCP-based photodetectors using a conductive metallic anode[J]. Nuclear Instruments & Methods in Physics Research, 2017, 846:75-80.

相似文献/References:

[1]张洋,黄永刚,刘辉,等.阳极氧化铝微通道板研究的进展[J].红外技术,2012,34(07):427.
 ZHANG Yang,HUANG Yong-gang,LIU Hui,et al.Progress in Anodic Aluminum Oxide Microchannel Plates[J].Infrared Technology,2012,34(11):427.
[2]刘术林,邓广绪,严诚,等.MCP增益与首次碰撞时电子能量关系的试验研究[J].红外技术,2011,33(06):354.
 LIU Shu-lin,DENG Guang-xu,YAN Cheng,et al.Experiment Research on Relation Between MCP Gainand Electron Energy While First Collision[J].Infrared Technology,2011,33(11):354.
[3]张 洋,黄永刚,刘 辉,等.微通道板双面抛光过程材料去除特性研究[J].红外技术,2014,36(4):336.[doi:10.11846/j.issn.1001_8891.201404016]
 ZHANG Yang,HUANG Yong-gang,LIU Hui,et al.Material Removal Property in Double-sided Polishing Process for Microchannel Plates [J].Infrared Technology,2014,36(11):336.[doi:10.11846/j.issn.1001_8891.201404016]
[4]潘京生,邵爱飞,孙建宁,等.微通道板的离子反馈对像增强器性能升级的影响分析及改进途径探究[J].红外技术,2015,37(四):327.[doi:10.11846/j.issn.1001_8891.201504013]
 PAN Jing-sheng,SHAO Ai-fei,SUN Jian-ning,et al.Influence Analysis of Ion Feedback of Microchannel Plate on Image Intensifiers Performance Upgrade and Its Improvement Approach Exploration[J].Infrared Technology,2015,37(11):327.[doi:10.11846/j.issn.1001_8891.201504013]
[5]杨露萍,刘术林,黄明举,等.提高微通道板对低能电子探测效率的技术途径[J].红外技术,2016,38(8):714.
 YANG Luping,LIU Shulin,HUANG Mingju,et al.Technical approach to improve the detective efficiency of Microchannel Plate for[J].Infrared Technology,2016,38(11):714.
[6]李丹,朱宇峰,赵慧民,等.MCP噪声因子特性研究[J].红外技术,2017,39(11):1066.[doi:10.11846/j.issn.1001_8891.201711016]
 LI Dan,ZHU Yufeng,ZHAO Huimin,et al.Research on Noise Factor Characteristic of Micro-channel Plate[J].Infrared Technology,2017,39(11):1066.[doi:10.11846/j.issn.1001_8891.201711016]
[7]郝子恒,李相鑫,张妮,等.微通道板高增益二次电子发射层制备研究[J].红外技术,2018,40(11):1077.[doi:10.11846/j.issn.1001_8891.201811010]
 HAO Ziheng,LI Xiangxin,ZHANG Ni,et al.Preparation of High Gain Secondary Electron Emission Layer for Micro-channel Plate[J].Infrared Technology,2018,40(11):1077.[doi:10.11846/j.issn.1001_8891.201811010]

备注/Memo

备注/Memo:
收稿日期:2018-07-15;修订日期:2018-10-26.
作者简介:潘京生(1965-),博士,研高,从事微通道板探测器的研究。E-mail:pjs@nvt.com.cn。

更新日期/Last Update: 2018-11-20